In clinical practice, plaster fragments may be bonded without har

In clinical practice, plaster fragments may be bonded without harming the accuracy of the final denture, provided that the bonding agent does not cause dimensional alterations. Cyanoacrylate could be a good material because of its ease of use, quick set, wide availability, and low cost. The aim www.selleckchem.com/products/sch772984.html of this study was to assess the dimensional alteration of Type IV plaster fragments bonded with a cyanoacrylate-based adhesive. Materials and Methods: Ten hexagonal regular prisms were made of Type IV plaster, with two reference marks on one of the faces. The distance between the marks was measured under a comparison microscope. After this, the prisms were fractured so that the fracture line would be between the two reference marks, bonded

with a cyanoacrylate-based universal adhesive

and measured again. Results: The mean difference between the measurements performed before and after fracture and bonding of the fragments was 0.0194 mm. At a level of significance of 0.05, there was no statistically significant difference between the measurements before and after fracture and bonding of the dies BMN 673 supplier (p = 0.1582). Conclusion: It may be concluded that bonding of Type IV plaster fragments with a cyanoacrylate-based adhesive did not cause significant dimensional alterations. “
“Purpose: This study evaluated the resistance to corrosion in welds made with Tungsten Inert Gas (TIG) in specimens made of commercially pure titanium (cp Ti) in comparison with laser buy Forskolin welds. Materials and Methods: A total of 15 circular specimens (10-mm diameter, 2-mm thick) were fabricated and divided into two groups: control group—cp Ti specimens (n = 5); experimental group—cp Ti specimens welded with TIG (n = 5) and with laser (n = 5). They were polished mechanically, washed with isopropyl alcohol, and dried with a drier. In the anodic potentiodynamic polarization assay, measurements were taken using a potentiostat/galvanostat in addition to CorrWare software for data acquisition and CorrView for data visualization and treatment.

Three curves were made for each working electrode. Corrosion potential values were statistically analyzed by the Student’s t-test. Results: Statistical analysis showed that corrosion potentials and passive current densities of specimens welded with TIG are similar to those of the control group, and had lower values than laser welding. TIG welding provided higher resistance to corrosion than laser welding. Conclusion: Control specimens welded with TIG were more resistant to local corrosion initiation and propagation than those with laser welding, indicating a higher rate of formation and growth of passive film thickness on the surfaces of these alloys than on specimens welded with laser, making it more difficult for corrosion to occur. “
“Purpose: This study evaluated the bond strength between resin cement and Y-TZP ceramic (Yttrium-stabilized Tetragonal Zirconia Polycrystalline) submitted to different surface conditionings.

Comments are closed.